Description
Cisco CBS350-16FP2G Dubai
The Cisco CBS350-16FP2G Dubai Network represents a 16-Port Gigabit PoE+ Compliant Managed Switch with SFP+, designed to augment your business’s network capacity and accommodate powered devices such as IP security cameras, wireless access points, VoIP phones, and more. This managed rackmount switch is equipped with 16 PoE+ compliant Gigabit Ethernet ports, offering a 240W budget to effectively power compatible devices. Additionally, it boasts two Gigabit SFP+ ports to facilitate high-speed fiber connections. Its comprehensive Layer 2 and Layer 3 functionalities encompass secure connections, seamless communications, and link aggregation, enabling the creation of up to eight groups of 16 ports for multi-Gig connections to compatible devices. Boasting a 20 Gb/s switching capacity and a 26.78 Mpps forwarding rate, the Cisco CBS350-16FP2G Dubai ensures seamless and reliable data transfers. Utilize the Cisco Business Dashboard portal and mobile app to configure and monitor the Cisco CBS350-16FP2G Dubai along with its interconnected devices. With its fanless design, the Cisco CBS350-16FP2G Dubai reduces power consumption while operating silently in the background, ensuring a noise-free environment.
Features
Reliable Performance
The Cisco CBS350-16FP2G Dubai is equipped with an 800 MHz ARM processor and 512MB of memory, which work to deliver smooth and reliable data transfers with a 20 Gb/s switching capacity and 26.78 Mpps forwarding rate.
Power over Ethernet
The Cisco CBS350-16FP2G Dubai has 16 PoE+ ports support up to 30W of power each, with a total budget of 240W to operate advanced surveillance cameras, videophones, thin client devices, and more.
Extensive Security
- Cisco CBS350-16FP2G Dubai has support for features such as IEEE 802.1x and port security limit access to specific segments of your network while web-based authentication provides a consistent interface to all types of host devices and operating systems.
- Advanced defense mechanisms, such as dynamic Address Resolution Protocol (ARP) inspection, IP Source Guard, and Dynamic Host Configuration Protocol (DHCP) snooping, help to detect and block network attacks. When combined, these protocols may be referred to as IP-MAC port binding (IPMB).
- The IPv6 First Hop Security suite includes ND inspection, RA guard, DHCPv6 guard, and neighbor binding integrity check to protect your IPv6 network against a range of address spoofing and man-in-the-middle attacks.
IPv6 Support
The Cisco CBS350-16FP2G Dubai switch allows you to evolve your network using the IPv6 standard while remaining compatible the previous-generation IPv4 networks.
Layer 3 Static Routing
Cisco CBS350-16FP2G Dubai switch features dynamic Layer 3 routing features include the ability to segment your network into separate workgroups and communicate across VLANs without degrading application performance, which allows you to manage your switch’s internal routing and dedicate your router to external traffic and security to help your network run efficiently.
True Stacking
Reduce the complexity of your network while enhancing your control over a growing network by configuring, managing, and troubleshooting all your switches in a stack as a single unit using a single IP address. True stacking capability in Cisco CBS350-16FP2G Dubai also provides other benefits through features such as cross-stack QoS, VLANs, LAGs, and port mirroring.
Compact Design
With a sleek and compact 1 RU design, the Cisco CBS350-16FP2G Dubai can fit into wiring closets and other installations within retail stores, offices, and other businesses.
Energy Efficient
Cisco CBS350-16FP2G Dubai has support for the Energy Efficient Ethernet (IEEE 802.3az) standard helps to significantly reduce energy consumption by monitoring the amount of traffic an active link receives and putting it to sleep during down times.
Specifications
Performance | ||||
Switching capacity and forwarding rate | Model | Capacity in millions of packets per second (64-byte packets) | Switching capacity in gigabits per second | |
CBS350-8T-E-2G | 14.88 mpps | 20.0 Gbps | ||
CBS350-8P-2G | 14.88 mpps | 20.0 Gbps | ||
CBS350-8P-E-2G | 14.88 mpps | 20.0 Gbps | ||
CBS350-8FP-2G | 14.88 mpps | 20.0 Gbps | ||
CBS350-8FP-E-2G | 14.88 mpps | 20.0 Gbps | ||
CBS350-8S-E-2G | 14.88 mpps | 20.0 Gbps | ||
CBS350-16T-2G | 26.78 mpps | 36.0 Gbps | ||
CBS350-16T-E-2G | 26.78 mpps | 36.0 Gbps | ||
CBS350-16P-2G | 26.78 mpps | 36.0 Gbps | ||
CBS350-16P-E-2G | 26.78 mpps | 36.0 Gbps | ||
CBS350-16FP-2G | 26.78 mpps | 36.0 Gbps | ||
CBS350-24T-4G | 41.66 mpps | 56.0 Gbps | ||
CBS350-24P-4G | 41.66 mpps | 56.0 Gbps | ||
CBS350-24FP-4G | 41.66 mpps | 56.0 Gbps | ||
CBS350-24S-4G | 41.66 mpps | 56.0 Gbps | ||
CBS350-48T-4G | 77.38 mpps | 104.0 Gbps | ||
CBS350-48P-4G | 77.38 mpps | 104.0 Gbps | ||
CBS350-48FP-4G | 77.38 mpps | 104.0 Gbps | ||
Layer 2 switching | ||||
Spanning Tree Protocol (STP) | Standard 802.1d spanning tree support
Fast convergence using 802.1w (Rapid Spanning Tree Protocol [RSTP]), enabled by default Multiple spanning tree instances using 802.1s (MSTP); 8 instances are supported Per-VLAN Spanning Tree Plus (PVST+) and Rapid PVST+ (RPVST+); 126 instances are supported |
|||
Port grouping/link aggregation | Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP)
Up to 8 groups Up to 8 ports per group with 16 candidate ports for each (dynamic) 802.3ad Link Aggregation Group (LAG) |
|||
VLAN | Support for up to 4,094 VLANs simultaneously
Port-based and 802.1Q tag-based VLANs; MAC-based VLAN; protocol-based VLAN; IP subnet-based VLAN Management VLAN Private VLAN with promiscuous, isolated, and community port Private VLAN Edge (PVE), also known as protected ports, with multiple uplinks Guest VLAN, unauthenticated VLAN Dynamic VLAN assignment via RADIUS server along with 802.1x client authentication CPE VLAN |
|||
Voice VLAN | Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoS. Auto voice capabilities deliver network wide zero-touch deployment of voice endpoints and call control devices | |||
Multicast TV VLAN | Multicast TV VLAN allows the single multicast VLAN to be shared in the network while subscribers remain in separate VLANs. This feature is also known as Multicast VLAN Registration (MVR) | |||
VLAN Translation | Support for VLAN One-to-One Mapping. In VLAN One-to-One Mapping, on an edge interface customer VLANs (C-VLANs) are mapped to service provider VLANs (S-VLANs) and the original C-VLAN tags are replaced by the specified S-VLAN | |||
Q-in-Q | VLANs transparently cross a service provider network while isolating traffic among customers | |||
Selective Q-in-Q | Selective Q-in-Q is an enhancement to the basic Q-in-Q feature and provides, per edge interface, multiple mappings of different C-VLANs to separate S-VLANs
Selective Q-in-Q also allows configuring of Ethertype (Tag Protocol Identifier [TPID]) of the S-VLAN tag Layer 2 protocol tunneling over Q-in-Q is also supported |
|||
Generic VLAN Registration Protocol (GVRP) and Generic Attribute Registration Protocol (GARP) | Generic VLAN Registration Protocol (GVRP) and Generic Attribute Registration Protocol (GARP) enable automatic propagation and configuration of VLANs in a bridged domain | |||
Unidirectional Link Detection (UDLD) | UDLD monitors physical connection to detect unidirectional links caused by incorrect wiring or cable/port faults to prevent forwarding loops and black holing of traffic in switched networks | |||
Dynamic Host Configuration Protocol (DHCP) Relay at Layer 2 | Relay of DHCP traffic to DHCP server in different VLAN; works with DHCP Option 82 | |||
IGMP (versions 1, 2, and 3) snooping | IGMP limits bandwidth-intensive multicast traffic to only the requesters; supports 2K multicast groups (source-specific multicasting is also supported) | |||
IGMP querier | IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router | |||
HOL blocking | Head-of-Line (HOL) blocking prevention | |||
Loopback detection | Loopback detection provides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STP | |||
Layer 3 routing | ||||
IPv4 routing | Wire-speed routing of IPv4 packets
Up to 990 static routes and up to 128 IP interfaces |
|||
IPv6 routing | Wire-speed routing of IPv6 packets | |||
Layer 3 interface | Configuration of Layer 3 interface on physical port, Link Aggregation (LAG), VLAN interface, or loopback interface | |||
Classless Interdomain Routing (CIDR) | Support for classless interdomain routing | |||
RIP v2 | Support for Routing Information Protocol version 2 for dynamic routing | |||
Policy-Based Routing (PBR) | Flexible routing control to direct packets to different next hop based on IPv4 or IPv6 Access Control List (ACL) | |||
DHCP Server | Switch functions as an IPv4 DHCP server serving IP addresses for multiple DHCP pools/scopes
Support for DHCP options |
|||
DHCP relay at Layer 3 | Relay of DHCP traffic across IP domains | |||
User Datagram Protocol (UDP) relay | Relay of broadcast information across Layer 3 domains for application discovery or relaying of Bootstrap Protocol (BOOTP)/DHCP packets | |||
Stacking | ||||
Hardware stacking | Up to 4 units in a stack. Up to 192 ports managed as a single system with hardware failover | |||
High availability | Fast stack failover delivers minimal traffic loss. Support link aggregation across multiple units in a stack | |||
Plug-and-play stacking configuration/management | Active/standby for resilient stack control
Autonumbering Hot swap of units in stack Ring and chain stacking options, auto stacking port speed, flexible stacking port options |
|||
High-speed stack interconnects | Cost-effective high-speed 10G fiber interfaces | |||
Security | ||||
Secure Sockets Layer (SSL) | SSL support : Encrypts all HTTPS traffic, allowing highly secure access to the browser-based management GUI in the switch | |||
Secure Shell (SSH) Protocol | SSH is a secure replacement for Telnet traffic. Secure Copy Protocol (SCP) also uses SSH. SSH v1 and v2 are supported | |||
IEEE 802.1X (authenticator role) | 802.1X : Remote Authentication Dial-In User Service (RADIUS) authentication and accounting, MD5 hash; guest VLAN; unauthenticated VLAN, single/multiple host mode and single/multiple sessions Supports time-based 802.1X; dynamic VLAN assignment |
|||
Web-based authentication | Web-based authentication provides network admission control through web browser to any host devices and operating systems | |||
STP Bridge Protocol Data Unit (BPDU) Guard | A security mechanism to protect the network from invalid configurations. A port enabled for BPDU Guard is shut down if a BPDU message is received on that port. This avoids accidental topology loops | |||
STP Root Guard | This prevents edge devices not in the network administrator’s control from becoming Spanning Tree Protocol root nodes | |||
STP loopback guard | Provides additional protection against Layer 2 forwarding loops (STP loops) | |||
DHCP snooping | Filters out DHCP messages with unregistered IP addresses and/or from unexpected or untrusted interfaces. This prevents rogue devices from behaving as DHCP Servers. | |||
IP Source Guard (IPSG) | When IP Source Guard is enabled at a port, the switch filters out IP packets received from the port if the source IP addresses of the packets have not been statically configured or dynamically learned from DHCP snooping. This prevents IP address spoofing. | |||
Dynamic ARP Inspection (DAI) | The switch discards ARP packets from a port if there are no static or dynamic IP/MAC bindings or if there is a discrepancy between the source or destination addresses in the ARP packet. This prevents man-in-the-middle attacks. | |||
IP/MAC/Port Binding (IPMB) | The preceding features (DHCP Snooping, IP Source Guard, and Dynamic ARP Inspection) work together to prevent DOS attacks in the network, thereby increasing network availability | |||
Secure Core Technology (SCT) | Makes sure that the switch will receive and process management and protocol traffic no matter how much traffic is received | |||
Secure Sensitive Data (SSD) | A mechanism to manage sensitive data (such as passwords, keys, and so on) securely on the switch, populating this data to other devices, and secure autoconfig. Access to view the sensitive data as plaintext or encrypted is provided according to the user-configured access level and the access method of the user. | |||
Trustworthy systems | Trustworthy systems provide a highly secure foundation for Cisco products
Run-time defenses (Executable Space Protection [X-Space], Address Space Layout Randomization [ASLR], Built-In Object Size Checking [BOSC]) |
|||
Private VLANMultiple user privilege levels in CLI | Private VLAN provides security and isolation between switch ports, which helps ensure that users cannot snoop on other users’ traffic; supports multiple uplinks | |||
Layer 2 isolation Private VLAN Edge (PVE) with community VLAN | PVE (also known as protected ports) provides Layer 2 isolation between devices in the same VLAN, supports multiple uplinks | |||
Port security | Ability to lock source MAC addresses to ports and limits the number of learned MAC addresses | |||
RADIUS/TACACS+ | Supports RADIUS and TACACS authentication. Switch functions as a client | |||
RADIUS accounting | The RADIUS accounting functions allow data to be sent at the start and end of services, indicating the amount of resources (such as time, packets, bytes, and so on) used during the session | |||
Storm control | Broadcast, multicast, and unknown unicast | |||
DoS prevention | Denial-of-Service (DOS) attack prevention | |||
Multiple user privilege levels in CLI | Level 1, 7, and 15 privilege levels | |||
ACLs | Support for up to 1,024 rules
Drop or rate limit based on source and destination MAC, VLAN ID, IPv4 or IPv6 address, IPv6 flow label, protocol, port, Differentiated Services Code Point (DSCP)/IP precedence, Transmission Control Protocol/User Datagram Protocol (TCP/UDP) source and destination ports, 802.1p priority, Ethernet type, Internet Control Message Protocol (ICMP) packets, IGMP packets, TCP flag; ACL can be applied on both ingress and egress sides Time-based ACLs supported |
|||
Quality of service | ||||
Priority levels | 8 hardware queues | |||
Scheduling | Strict priority and Weighted Round-Robin (WRR) | |||
Class of service | Port based; 802.1p VLAN priority-based; IPv4/v6 IP precedence/Type of Service (ToS)/DSCP-based; Differentiated Services (DiffServ); classification and remarking ACLs, trusted QoS Queue assignment based on DSCP and class of service (802.1p/CoS) |
|||
Rate limiting | Ingress policer; egress shaping and rate control; per VLAN, per port, and flow based; 2R3C policing | |||
Congestion avoidance | A TCP congestion avoidance algorithm is required to minimize and prevent global TCP loss synchronization | |||
iSCSI traffic optimization | A mechanism for giving priority to iSCSI traffic over other types of traffic | |||
Standards | ||||
Standards | IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3ae 10 Gbit/s Ethernet over fiber for LAN, IEEE 802.3an 10GBase-T 10 Gbit/s Ethernet over copper twisted pair cable, IEEE 802.3x Flow Control, IEEE 802.1D (STP, GARP, and GVRP), IEEE 802.1Q/p VLAN, IEEE 802.1w Rapid STP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, IEEE 802.1AB Link Layer Discovery Protocol, IEEE 802.3az Energy Efficient Ethernet, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793, RFC 813, RFC 826, RFC 879, RFC 896, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC 919, RFC 920, RFC 922, RFC 950, RFC 951, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1213, RFC 1215, RFC 1286, RFC 1350, RFC 1442, RFC 1451, RFC 1493, RFC 1533, RFC 1541, RFC 1542, RFC 1573, RFC 1624, RFC 1643, RFC 1700, RFC 1757, RFC 1867, RFC 1907, RFC 2011, RFC 2012, RFC 2013, RFC 2030, RFC 2131, RFC 2132, RFC 2233, RFC 2576, RFC 2616, RFC 2618, RFC 2665, RFC 2666, RFC 2674, RFC 2737, RFC 2819, RFC 2863, RFC 3164, RFC 3176, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 3416, RFC 4330 | |||
IPv6 | ||||
IPv6 | IPv6 host mode; IPv6 over Ethernet; Dual IPv6/IPv4 stack
IPv6 neighbor and router discovery (ND); IPv6 stateless address autoconfiguration; Path Maximum Transmission Unit (MTU) discovery Duplicate Address Detection (DAD); ICMP version 6 DHCPv6 stateful client IPv6 over IPv4 network with Intrasite Automatic Tunnel Addressing Protocol (ISATAP) support USGv6 and IPv6 Gold Logo certified |
|||
IPv6 QoS | Prioritize IPv6 packets in hardware | |||
IPv6 ACL | Drop or rate limit IPv6 packets in hardware | |||
IPv6 First Hop Security | RA guard
ND inspection DHCPv6 guard Neighbor binding table (snooping and static entries) Neighbor binding integrity check |
|||
Multicast Listener Discovery (MLD v1/2) snooping | Deliver IPv6 multicast packets only to the required receivers | |||
IPv6 applications |
Web/SSL, Telnet server/SSH, ping, traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), SNMP, RADIUS, syslog, Domain Name System (DNS) client, Telnet Client, DHCP Client, DHCP Autoconfig, IPv6 DHCP Relay, Terminal Access Controller Access Control System Plus (TACACS+) |
|||
IPv6 RFCs supported | RFC 4443 (which obsoletes RFC 2463) : ICMPv6
RFC 4291 (which obsoletes RFC 3513) : IPv6 address architecture RFC 4291 : IPv6 Addressing Architecture RFC 2460 : IPv6 Specification RFC 4861 (which obsoletes RFC 2461) : Neighbor Discovery for IPv6 RFC 4862 (which obsoletes RFC 2462) : IPv6 Stateless Address Autoconfiguration RFC 1981 : Path MTU Discovery RFC 4007 : IPv6 Scoped Address Architecture RFC 3484 : Default address selection mechanism RFC 5214 (which obsoletes RFC 4214) : ISATAP tunneling RFC 4293 : Management Information Base (MIB) IPv6 : Textual Conventions and General Group RFC 3595 : Textual Conventions for IPv6 Flow Label |
|||
Management | ||||
Cisco Business Dashboard | Support for embedded probe for Cisco Business Dashboard running on the switch. Eliminates the need to set up a separate hardware or virtual machine for the Cisco Business Dashboard Probe on site. | |||
Cisco Business mobile app | Mobile app for Cisco Business Switch and Wireless products. Helps to set up a local network in minutes and provide easy management at your fingertips. | |||
Cisco Network Plug and Play (PnP) agent | The Cisco Network Plug and Play solution provides a simple, secure, unified, and integrated offering to ease new branch or campus device rollouts or for provisioning updates to an existing network. The solution provides a unified approach to provision Cisco routers, switches, and wireless devices with a near-zero-touch deployment experience.
Supports Cisco PnP Connect |
|||
Web user interface | Built-in switch configuration utility for easy browser-based device configuration (HTTP/HTTPS). Supports configuration, wizards, system dashboard, system maintenance, and monitoring
Basic and advanced mode for maximum operational efficiency |
|||
SNMP | SNMP versions 1, 2c, and 3 with support for traps, and SNMP v3 User-based Security Model (USM) | |||
Standard MIBs | lldp-MIB
lldpextdot1-MIB lldpextdot3-MIB lldpextmed-MIB rfc2674-MIB rfc2575-MIB rfc2573-MIB rfc2233-MIB rfc2013-MIB rfc2012-MIB rfc2011-MIB RFC-1212 RFC-1215 SNMPv2-CONF SNMPv2-TC p-bridge-MIB q-bridge-MIB rfc1389-MIB rfc1493-MIB rfc1611-MIB rfc1612-MIB rfc1850-MIB rfc1907-MIB rfc2571-MIB rfc2572-MIB rfc2574-MIB rfc2576-MIB rfc2613-MIB rfc2665-MIB |
rfc2668-MIB
rfc2737-MIB rfc2925-MIB rfc3621-MIB rfc4668-MIB rfc4670-MIB trunk-MIB tunnel-MIB udp-MIB draft-ietf-bridge-8021x-MIB draft-ietf-bridge-rstpmib-04-MIB draft-ietf-hubmib-etherif-mib-v3-00-MIB draft-ietf-syslog-device-MIB ianaaddrfamnumbers-MIB ianaifty-MIB ianaprot-MIB inet-address-MIB ip-forward-MIB ip-MIB RFC1155-SMI RFC1213-MIB SNMPv2-MIB SNMPv2-SMI SNMPv2-TM RMON-MIB rfc1724-MIB dcb-raj-DCBX-MIB-1108-MIB rfc1213-MIB rfc1757-MIB |
||
Private MIBs | CISCOSB-lldp-MIB
CISCOSB-brgmulticast-MIB CISCOSB-bridgemibobjects-MIB CISCOSB-bonjour-MIB CISCOSB-dhcpcl-MIB CISCOSB-MIB CISCOSB-wrandomtaildrop-MIB CISCOSB-traceroute-MIB CISCOSB-telnet-MIB CISCOSB-stormctrl-MIB CISCOSBssh-MIB CISCOSB-socket-MIB CISCOSB-sntp-MIB CISCOSB-smon-MIB CISCOSB-phy-MIB CISCOSB-multisessionterminal-MIB CISCOSB-mri-MIB CISCOSB-jumboframes-MIB CISCOSB-gvrp-MIB CISCOSB-endofmib-MIB CISCOSB-dot1x-MIB CISCOSB-deviceparams-MIB CISCOSB-cli-MIB CISCOSB-cdb-MIB CISCOSB-brgmacswitch-MIB CISCOSB-3sw2swtables-MIB CISCOSB-smartPorts-MIB CISCOSB-tbi-MIB CISCOSB-macbaseprio-MIB CISCOSB-env_mib-MIB CISCOSB-policy-MIB CISCOSB-sensor-MIB CISCOSB-aaa-MIB CISCOSB-application-MIB CISCOSB-bridgesecurity-MIB CISCOSB-copy-MIB CISCOSB-CpuCounters-MIB CISCOSB-Custom1BonjourService-MIB CISCOSB-dhcp-MIB CISCOSB-dlf-MIB CISCOSB-dnscl-MIB CISCOSB-embweb-MIB CISCOSB-fft-MIB CISCOSB-file-MIB CISCOSB-greeneth-MIB CISCOSB-interfaces-MIB CISCOSB-interfaces_recovery-MIB |
CISCOSB-ip-MIB
CISCOSB-iprouter-MIB CISCOSB-ipv6-MIB CISCOSB-mnginf-MIB CISCOSB-lcli-MIB CISCOSB-localization-MIB CISCOSB-mcmngr-MIB CISCOSB-mng-MIB CISCOSB-physdescription-MIB CISCOSB-PoE-MIB CISCOSB-protectedport-MIB CISCOSB-rmon-MIB CISCOSB-rs232-MIB CISCOSB-SecuritySuite-MIB CISCOSB-snmp-MIB CISCOSB-specialbpdu-MIB CISCOSB-banner-MIB CISCOSB-syslog-MIB CISCOSB-TcpSession-MIB CISCOSB-traps-MIB CISCOSB-trunk-MIB CISCOSB-tuning-MIB CISCOSB-tunnel-MIB CISCOSB-udp-MIB CISCOSB-vlan-MIB CISCOSB-ipstdacl-MIB CISCOSB-eee-MIB CISCOSB-ssl-MIB CISCOSB-qosclimib-MIB CISCOSB-digitalkeymanage-MIB CISCOSB-tbp-MIB CISCOSMB-MIB CISCOSB-secsd-MIB CISCOSB-draft-ietf-entmib-sensor-MIB CISCOSB-draft-ietf-syslog-device-MIB CISCOSB-rfc2925-MIB CISCO-SMI-MIB CISCOSB-DebugCapabilities-MIB CISCOSB-CDP-MIB CISCOSB-vlanVoice-MIB CISCOSB-EVENTS-MIB CISCOSB-sysmng-MIB CISCOSB-sct-MIB CISCO-TC-MIB CISCO-VTP-MIB CISCO-CDP-MIB |
||
Remote monitoring (RMON) | Embedded RMON software agent supports 4 RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis | |||
IPv4 and IPv6 dual stack | Coexistence of both protocol stacks to ease migration | |||
Firmware upgrade | Web browser upgrade (HTTP/HTTPS) and TFTP and upgrade over SCP running over SSH
Dual images for resilient firmware upgrades |
|||
Port mirroring | Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe. Up to 4 source ports can be mirrored to one destination port | |||
VLAN mirroring | Traffic from a VLAN can be mirrored to a port for analysis with a network analyzer or RMON probe. Up to 4 source VLANs can be mirrored to one destination port | |||
Dynamic Host Configuration Protocol (DHCP) (options 12, 66, 67, 129, and 150) | DHCP options facilitate tighter control from a central point (DHCP server), to obtain IP address, autoconfiguration (with configuration file download), DHCP Relay, and host name | |||
Secure Copy (SCP) | Securely transfers files to and from the switch | |||
Autoconfiguration with SCP file download | Enables mass deployment with protection of sensitive data | |||
Text-editable configs | Config files can be edited with a text editor and downloaded to another switch, facilitating easier mass deployment | |||
Smartports | Simplified configuration of QoS and security capabilities | |||
Auto Smartports | Automatically applies the intelligence delivered through the Smartports roles to the port based on the devices discovered over Cisco Discovery Protocol or LLDP-MED. This facilitates zero-touch deployments. | |||
Text view Command-Line Interface (CLI) | Scriptable CLI. A full CLI as well as a menu-based CLI is supported. User privilege levels 1, 7, and 15 are supported for the CLI. | |||
Localization | Localization of GUI and documentation into multiple languages | |||
Login banner | Configurable multiple banners for web as well as CLI | |||
Other management | Traceroute; single IP management; HTTP/HTTPS; RADIUS; port mirroring; TFTP upgrade; DHCP client; Simple Network Time Protocol (SNTP); cable diagnostics; Ping; syslog; Telnet client (SSH secure support); automatic time settings from Management Station | |||
Green (Power Efficiency) | ||||
Energy detect | Automatically turns power off on RJ-45 port when detecting link down. Active mode is resumed without loss of any packets when the switch detects the link is up | |||
Cable length detection | Adjusts the signal strength based on the cable length. Reduces the power consumption for shorter cables | |||
EEE compliant (802.3az) | Supports IEEE 802.3az on all copper Gigabit Ethernet ports | |||
Disable port LEDs | LEDs can be manually turned off to save on energy | |||
Time-based port operation | Link up or down based on user-defined schedule (when the port is administratively up) | |||
Time-based PoE | PoE power can be on or off based on user-defined schedule to save energy | |||
General | ||||
Jumbo frames | Frame sizes up to 9K bytes. The default MTU is 2K bytes | |||
MAC table | 16K addresses | |||
Discovery | ||||
Bonjour | The switch advertises itself using the Bonjour protocol | |||
Link Layer Discovery Protocol (LLDP) (802.1ab) with LLDP-MED extensions | Link Layer Discovery Protocol (LLDP) allows the switch to advertise its identification, configuration, and capabilities to neighboring devices that store the data in a MIB. LLDP-MED is an enhancement to LLDP that adds the extensions needed for IP phones | |||
Cisco Discovery Protocol | The switch advertises itself using the Cisco Discovery Protocol. It also learns the connected device and its characteristics using Cisco Discovery Protocol | |||
Power over Ethernet (PoE) | ||||
802.3af PoE, 802.3at PoE+ or 60W PoE delivered over the RJ-45 ports within the listed power budgets | The following switches support 802.3at PoE+, 802.3af, and Cisco prestandard (legacy) PoE. 60W PoE is also supported on select RJ-45 network ports on select models. The total power available for PoE per switch is as follows : | |||
Model | Power dedicated to PoE | Number of ports that support PoE | ||
CBS350-8P-2G | 67W | 8 | ||
CBS350-8P-E-2G | 60W | 8 | ||
CBS350-8FP-2G | 120W | 8 | ||
CBS350-8FP-E-2G | 120W | 8 | ||
CBS350-16P-2G | 120W | 16 | ||
CBS350-16P-E-2G | 120W | 16 | ||
CBS350-16FP-2G | 120W | 16 | ||
CBS350-24P-4G | 240W | 24 | ||
CBS350-24FP-4G | 195W | 24 | ||
CBS350-48P-4G | 370W | 48 | ||
CBS350-48FP-4G | 370W | 48 | ||
Power consumption (worst case) | Model | System power consumption | Power consumption (with PoE) | Heat dissipation (BTU/hr) |
CBS350-8T-E-2G | 110V=12.55W 220V=12.56W |
N/A | 42.86 | |
CBS350-8P-2G | 110V=17.35W 220V=17.95W |
110V=83.17W 220V=82.63W |
283.79 | |
CBS350-8P-E-2G | 110V=13.84W 220V=14.31W |
110V=80.79W 220V=80.86W |
275.91 | |
CBS350-8FP-2G | 110V=17.29W 220V=17.88W |
110V=148.12W 220V=146.36W |
505.41 | |
CBS350-8FP-E-2G | 110V=17.07W 220V=16.68W |
110V=147.48W 220V=145.26W |
503.22 | |
CBS350-8S-E-2G | 110V=11.1W 220V=11.9W |
N/A | 40.6 | |
CBS350-16T-2G | 110V=18.63W 220V=18.37W |
N/A | 64.46 | |
CBS350-16T-E-2G | 110V=19.63W 220V=19.32W |
N/A | 65.92 | |
CBS350-16P-2G | 110V=24.51W 220V=25.01W |
110V=156.4W 220V=154.5W |
536.39 | |
CBS350-16P-E-2G | 110V=23.65W 220V=23.68W |
110V=150.1W 220V=148.8W |
512.16 | |
CBS350-16FP-2G | 110V=27.53W 220V=26.68W |
110V=284W 220V=279.8W |
971.78 | |
CBS350-24T-4G | 110V=25.91W 220V=25.63W |
N/A | 89.13 | |
CBS350-24P-4G | 110V=34.42W 220V=33.09W |
110V=239.7W 220V=236.4W |
820.62 | |
CBS350-24FP-4G | 110V=46.60W 220V=46.35W |
110V=449.7W 220V=438.3W |
1,537.17 | |
CBS350-24S-4G | 110V=32.0W 220V=34.3W |
N/A | 117.0 | |
CBS350-48T-4G | 110V=48.27W 220V=48.64W |
N/A | 165.96 | |
CBS350-48P-4G | 110V=60.77W 220V=59.73W |
110V=451.95W 220V=445.85W |
1,542.12 | |
CBS350-48FP-4G | 110V=73.79W 220V=74.03W |
110V=886.42W 220V=859.50W |
3,024.59 | |
Ports | Model name | Total system ports | RJ-45 ports | Combo ports (RJ-45 + SFP) |
CBS350-8T-E-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Gigabit Ethernet combo | |
CBS350-8P-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Gigabit Ethernet combo | |
CBS350-8P-E-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Gigabit Ethernet combo | |
CBS350-8FP-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Gigabit Ethernet combo | |
CBS350-8FP-E-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Gigabit Ethernet combo | |
CBS350-8S-E-2G | 10 x Gigabit Ethernet | 8 x Gigabit SFP Slots | 2 x Gigabit Ethernet combo | |
CBS350-16T-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2 x SFP | |
CBS350-16T-E-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2 x SFP | |
CBS350-16P-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2 x SFP | |
CBS350-16P-E-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2 x SFP | |
CBS350-16FP-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2 x SFP | |
CBS350-24T-4G | 28 x Gigabit Ethernet | 24 x Gigabit Ethernet | 4 x SFP | |
CBS350-24P-4G | 28 x Gigabit Ethernet | 24 x Gigabit Ethernet | 4 x SFP | |
CBS350-24FP-4G | 28 x Gigabit Ethernet | 24 x Gigabit Ethernet | 4 x SFP | |
CBS350-24S-4G | 28 x Gigabit Ethernet | 24 x Gigabit SFP Slots | 4 x SFP | |
CBS350-48T-4G | 52 x Gigabit Ethernet | 48 x Gigabit Ethernet | 4 x SFP | |
CBS350-48P-4G | 52 x Gigabit Ethernet | 48 x Gigabit Ethernet | 4 x SFP | |
CBS350-48FP-4G | 52 x Gigabit Ethernet | 48 x Gigabit Ethernet | 4 x SFP | |
Console port | Cisco standard mini USB Type-B/RJ45 console port : CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G, CBS350-16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G
Cisco standard RJ45 console port : CBS350-8S-E-2G, CBS350-24S-4G |
|||
USB slot | USB Type-A slot on the front panel of the switch for easy file and image management | |||
Buttons | Reset button | |||
Cabling type | Unshielded Twisted Pair (UTP) Category 5e or better for 1000BASE-T | |||
LEDs | System, Link/Act, PoE, Speed | |||
Flash | 256 MB | |||
CPU | 800 MHz ARM | |||
DRAM | 512 MB | |||
Packet buffer | All numbers are aggregate across all ports because the buffers are dynamically shared : | |||
Model name | Packet buffer | |||
CBS350-8T-E-2G | 1.5 MB | |||
CBS350-8P-2G | 1.5 MB | |||
CBS350-8P-E-2G | 1.5 MB | |||
CBS350-8FP-2G | 1.5 MB | |||
CBS350-8FP-E-2G | 1.5 MB | |||
CBS350-8S-E-2G | 1.5 MB | |||
CBS350-16T-2G | 1.5 MB | |||
CBS350-16T-E-2G | 1.5 MB | |||
CBS350-16P-2G | 1.5 MB | |||
CBS350-16P-E-2G | 1.5 MB | |||
CBS350-16FP-2G | 1.5 MB | |||
CBS350-24T-4G | 1.5 MB | |||
CBS350-24P-4G | 1.5 MB | |||
CBS350-24FP-4G | 1.5 MB | |||
CBS350-24S-4G | 1.5 MB | |||
CBS350-48T-4G | 3 MB | |||
CBS350-48P-4G | 3 MB | |||
CBS350-48FP-4G | 3 MB | |||
Supported SFP/SFP+ modules | SKU | Media | Speed | Maximum distance |
MGBSX1 | Multimode fiber | 1000 Mbps | 500 m | |
MGBLH1 | Single-mode fiber | 1000 Mbps | 40 km | |
MGBLX1 | Single-mode fiber | 1000 Mbps | 10 km | |
MGBT1 | UTP cat 5e | 1000 Mbps | 100 m | |
GLC-SX-MMD | Multimode fiber | 1000 Mbps | 550 m | |
GLC-LH-SMD | Single-mode fiber | 1000 Mbps | 10 km | |
GLC-BX-U | Single-mode fiber | 1000 Mbps | 10 km | |
GLC-BX-D | Single-mode fiber | 1000 Mbps | 10 km | |
GLC-TE | UTP cat 5e | 1000 Mbps | 100 m | |
SFP-H10GB-CU1M | Copper coax | 10 Gig | 1 m | |
SFP-H10GB-CU3M | Copper coax | 10 Gig | 3 m | |
SFP-H10GB-CU5M | Copper coax | 10 Gig | 5 m | |
SFP-10G-SR | Multimode fiber | 10 Gig | 26 m – 400 m | |
SFP-10G-LR | Single-mode fiber | 10 Gig | 10 km | |
SFP-10G-SR-S | Multimode fiber | 10 Gig | 26 m – 400 m | |
SFP-10G-LR-S | Single-mode fiber | 10 Gig | 10 km | |
Environmental | ||||
Unit dimensions (W x D x H) |
Model name | Unit dimensions | ||
CBS350-8T-E-2G | 268 x 185 x 44 mm (10.56 x 7.28 x 1.73 in) | |||
CBS350-8P-2G | 268 x 272 x 44 mm (10.56 x 10.71 x 1.73 in) | |||
CBS350-8P-E-2G | 268 x 185 x 44 mm (10.56 x 7.28 x 1.73 in) | |||
CBS350-8FP-2G | 268 x 272 x 44 mm (10.56 x 10.71 x 1.73 in) | |||
CBS350-8FP-E-2G | 268 x 185 x 44 mm (10.56 x 7.28 x 1.73 in) | |||
CBS350-8S-E-2G | 280 x 170 x 44 mm (11.0 x 6.69 x 1.73 in) | |||
CBS350-16T-2G | 268 x 272 x 44 mm (10.56 x 10.69 x 1.73 in) | |||
CBS350-16T-E-2G | 268 x 210 x 44 mm (10.56 x 8.26 x 1.73 in) | |||
CBS350-16P-2G | 268 x 297 x 44 mm (10.56 x 11.69 x 1.73 in) | |||
CBS350-16P-E-2G | 268 x 210 x 44 mm (10.56 x 8.26x 1.73 in) | |||
CBS350-16FP-2G | 268 x 308 x 44 mm (10.56 x 12.14 x 1.73 in) | |||
CBS350-24T-4G | 445 x 240 x 44 mm (17.5 x 9.45 x 1.73 in) | |||
CBS350-24P-4G | 445 x 299 x 44 mm (17.5 x 11.77 x 1.73 in) | |||
CBS350-24FP-4G | 445 x 345 x 44 mm (17.5 x 13.59 x 1.73 in) | |||
CBS350-24S-4G | 440 x 203 x 44 mm (17.3 x 7.99 x 1.73 in) | |||
CBS350-48T-4G | 445 x 288 x 44 mm (17.5 x 11.33 x 1.73 in) | |||
CBS350-48P-4G | 445 x 350 x 44 mm (17.5 x 13.78 x 1.73 in) | |||
CBS350-48FP-4G | 445 x 350 x 44 mm (17.5 x 13.78 x 1.73 in) | |||
Unit weight | Model name | Unit weight | ||
CBS350-8T-E-2G | 1.39 kg (3.06 lb) | |||
CBS350-8P-2G | 2.59 kg (5.71 lb) | |||
CBS350-8P-E-2G | 1.53 kg (3.37 lb) | |||
CBS350-8FP-2G | 2.59 kg (5.71 lb) | |||
CBS350-8FP-E-2G | 1.53 kg (3.37 lb) | |||
CBS350-8S-E-2G | 1.0 kg (2.20 lb) | |||
CBS350-16T-2G | 1.78 kg (3.92 lb) | |||
CBS350-16T-E-2G | 1.42 kg (3.13 lb) | |||
CBS350-16P-2G | 2.38 kg (5.25 lb) | |||
CBS350-16P-E-2G | 1.42 kg (3.13 lb) | |||
CBS350-16FP-2G | 2.49 kg (5.49 lb) | |||
CBS350-24T-4G | 2.63 kg (5.80 lb) | |||
CBS350-24P-4G | 3.53 kg (7.78 lb) | |||
CBS350-24FP-4G | 4.6 kg (10.14 lb) | |||
CBS350-24S-4G | 2.7 kg (5.95 lb) | |||
CBS350-48T-4G | 3.95 kg (8.71 lb) | |||
CBS350-48P-4G | 5.43 kg (11.97 lb) | |||
CBS350-48FP-4G | 5.82 kg (12.83 lb) | |||
Power | 100-240V 50-60 Hz, internal, universal : CBS350-8P-2G, CBS350-8FP-2G, CBS350-16T-2G, CBS350-16P-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-24S-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G 100-240V 50-60 Hz, external : CBS350-8T-E-2G, CBS350-8P-E-2G, CBS350-8FP-E-2G, CBS350-8S-E-2G, CBS350-16T-E-2G, CBS350-16P-E-2G |
|||
Certification | UL (UL 60950), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A | |||
Operating temperature | 23° to 122°F (-5° to 50°C) CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G, CBS350-16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G 32° to 122°F (0° to 50°C) CBS350-8S-E-2G, CBS350-24S-4G |
|||
Storage temperature | -13° to 158°F (-25° to 70°C) | |||
Operating humidity | 10% to 90%, relative, non-condensing | |||
Storage humidity | 10% to 90%, relative, non-condensing | |||
Acoustic noise and Mean Time Between Failures (MTBF) | Model name | Fan (number) | Acoustic noise | MTBF at 25°C (hours) |
CBS350-8T-E-2G | Fanless | N/A | 2,171,669 | |
CBS350-8P-2G | Fanless | N/A | 1,786,412 | |
CBS350-8P-E-2G | Fanless | N/A | 1,706,649 | |
CBS350-8FP-2G | Fanless | N/A | 1,786,412 | |
CBS350-8FP-E-2G | Fanless | N/A | 1,706,649 | |
CBS350-8S-E-2G | Fanless | N/A | 2,242,229 | |
CBS350-16T-2G | Fanless | N/A | 2,165,105 | |
CBS350-16T-E-2G | Fanless | N/A | 2,165,105 | |
CBS350-16P-2G | Fanless | N/A | 706,983 | |
CBS350-16P-E-2G | Fanless | N/A | 706,983 | |
CBS350-16FP-2G | Fanless | N/A | 706,983 | |
CBS350-24T-4G | Fanless | N/A | 2,026,793 | |
CBS350-24P-4G | Fanless | N/A | 698,220 | |
CBS350-24FP-4G | 1 | 25°C : 34.8 dBA | 698,220 | |
CBS350-24S-4G | Fanless | N/A | 258,544 | |
CBS350-48T-4G | 1 | 25°C : 29.7 dBA | 1,452,667 | |
CBS350-48P-4G | 1 | 25°C : 37.3 dBA | 856,329 | |
CBS350-48FP-4G | 1 | 25°C : 48.7 dBA | 856,301 |