Cisco CBS350-48P4G Dubai

Cisco CBS350-48P4G Dubai

The Cisco CBS350-48P4G Dubai Switch ensures secure connectivity within small offices, enabling smooth communication between employees and various network devices such as servers and printers.

Category:

Description

Cisco CBS350-48P4G Dubai

The Cisco CBS350-48P4G Dubai Switch ensures secure connectivity within small offices, enabling smooth communication between employees and various network devices such as servers and printers. With Cisco CBS350-48P4G Dubai high performance and reliable connectivity, Cisco CBS350-48P4G Dubai switch expedites file transfers and data processing, enhances network uptime, and fosters continuous productivity among your workforce. Its user-friendly dashboard streamlines network setup, while its advanced features promote digital transformation, all fortified by robust security measures safeguarding critical business transactions. Offering a balance of affordability and functionality, the Cisco CBS350-48P4G Dubai Switch is an optimal choice for small office setups, fostering a more efficient and interconnected workforce.

Functioning as a managed network solution, the Cisco CBS350-48P4G Dubai Switch delivers the necessary performance and intelligent traffic handling for seamless communication and data transfer across a unified network. Complementing its capabilities, Cisco presents a comprehensive range of IP telephony and unified communications products tailored for businesses. Rigorously tested for seamless integration and compatibility, the Cisco CBS350-48P4G Dubai Switch seamlessly integrates with these offerings, providing a holistic business solution.

Features

Simple Management and Deployment

Cisco CBS350-48P4G Dubai switch is designed to be easy to use and manage by commercial customers or the partners that serve them, including the following features:

  • Cisco Business Dashboard simplifies traditional challenges in deploying and managing business networks while automating the deployment, monitoring, and lifecycle management of the network. Cisco CBS350-48P4G Dubai switch supports embedded probe for Cisco Business Dashboard, eliminating the need to set up a separate hardware or virtual machine on site.
  • The Cisco Network Plug and Play solution provides a simple, secure, unified, and integrated offering to ease new device rollouts or for provisioning updates to an existing network. The solution provides a unified approach to provision Cisco routers, switches, and wireless devices with a near-zero-touch deployment experience.
  • The intuitive user interfaces reduce the time required to deploy, troubleshoot, and manage the network and allow you to support sophisticated capabilities without increasing IT head count.
  • The switches also support Text view, a full Command-Line Interface (CLI) option for partners that prefer it.
  • Cisco CBS350-48P4G Dubai has support for Simple Network Management Protocol (SNMP) allows you to set up and manage your switches and other Cisco devices remotely from a network management station, improving IT workflow and mass configurations.

High Reliability and Resiliency

The Cisco CBS350-48P4G Dubai supports dual images, allowing you to perform software upgrades without having to take the network offline or worry about the network going down during the upgrade.

Secure your Work

Cisco CBS350-48P4G Dubai provides the advanced security features you need to protect your business data and keep unauthorized users off the network:

  • Support for advanced network security applications such as IEEE 802.1X and port security tightly limits access to specific segments of your network. Web-based authentication provides a consistent interface to authenticate all types of host devices and operating systems, without the complexity of deploying IEEE 802.1X clients on each endpoint.
  • Advanced defense mechanisms, including dynamic Address Resolution Protocol (ARP) inspection, IP Source Guard, and Dynamic Host Configuration Protocol (DHCP) snooping, detect and block deliberate network attacks. Combinations of these protocols are also referred to as IP-MAC port binding (IPMB).
  • IPv6 First Hop Security extends the advanced threat protection to IPv6. This comprehensive security suite includes ND inspection, RA guard, DHCPv6 guard, and neighbor binding integrity check, providing unparalleled protection against a vast range of address spoofing and man-in-the-middle attacks on IPv6 networks.

Power over Ethernet

Cisco Business 350 Series Switches are available with up to 48 Power over Ethernet (PoE) ports. This capability simplifies advanced technology deployments such as IP telephony, wireless, and IP surveillance by allowing you to connect and power network endpoints over a single Ethernet cable. With no need to install separate power supplies for IP phones or wireless access points, you can take advantage of advanced communications technologies more quickly and at a lower cost. Models support 802.3af PoE and 802.3at PoE+. 60W PoE is also supported on select switches to power high-performance wireless access points and Internet of Things (IoT) devices.

IPv6 Support

As the IP address scheme evolves to accommodate a growing number of network devices, the Cisco Business 350 Series Switches can support the transition to the next generation of networking. These switches continue to support previous-generation IPv4, allowing you to evolve to the new IPv6 standard at your own pace and helping ensure that your current network will continue to support your business applications in the future. Cisco Business 350 Series Switches have successfully completed rigorous IPv6 testing and have received the USGv6 and IPv6 Gold certification.

Advanced Layer 3 Traffic Management

The Cisco Business 350 Series Switches enable a more advanced set of traffic management capabilities to help growing businesses organize their networks more effectively and efficiently. For example, the switches provide dynamic Layer 3 routing, allowing you to segment your network into workgroups and communicate across VLANs without degrading application performance.

With these capabilities, you can boost the efficiency of your network by offloading internal traffic-handling tasks from your router and allowing it to manage primarily external traffic and security.

True stacking

The Cisco CBS350-48P4G Dubai provides true stacking capability, allowing you to configure, manage, and troubleshoot all switches in a stack as a single unit with a single IP address. A true stack delivers a unified data and control plane, in addition to management plane, providing flexibility, scalability, and ease of use because the stack of units operates as a single entity constituting all the ports of the stack members. This capability can radically reduce complexity in a growing network environment while improving the resiliency and availability of network applications. True stacking also provides other cost savings and administrative benefits through features such as cross-stack QoS, VLANs, LAGs, and port mirroring, which clustered switches cannot support.

Compact Design

The sleek and compact design for the Cisco CBS350-48P4G Dubai provides additional deployment flexibility, including outside wiring closet installation such as retail stores, open plan offices, and classrooms without disturbing the environment.

Power Efficiency

The Cisco CBS350-48P4G Dubai Switch integrates a variety of power-saving features across all models, providing the industry’s most extensive energy-efficient switching portfolio. This switch is designed to conserve energy by optimizing power use, which helps protects the environment and reduce your energy costs. They provide an eco-friendly network solution without compromising performance. Cisco Business 350 Series Switches feature:

  • Support for the Energy Efficient Ethernet (IEEE 802.3az) standard, which reduces energy consumption by monitoring the amount of traffic on an active link and putting the link into a sleep state during quiet periods
  • Automatic power shutoff on ports when a link is down
  • Cisco CBS350-48P4G Dubai has embedded intelligence to adjust signal strength based on the length of the connecting cable
  • Cisco CBS350-48P4G Dubai has fanless design which reduces power consumption, increases reliability, and provides quieter operation

Peace of Mind and Investment Protection

Cisco CBS350-48P4G Dubai Switch offers the reliable performance and peace of mind you expect from a Cisco switch. A solution that has been rigorously tested to help ensure optimal network uptime to ensure business continuity. Complementary one-year access to our Small Business Support Center for ongoing support.

Specifications

Performance
Switching capacity and forwarding rate

All switches are wire speed and nonblocking

Model Name Capacity in Millions of Packets per Second (mpps) (64-byte packets) Switching Capacity in Gigabits per Second (Gbps)
CBS350-8T-E-2G 14.88 20.0
CBS350-8P-2G 14.88 20.0
CBS350-8P-E-2G 14.88 20.0
CBS350-8FP-2G 14.88 20.0
CBS350-8FP-E-2G 14.88 20.0
CBS350-8S-E-2G 14.88 20.0
CBS350-16T-2G 26.78 36.0
CBS350-16T-E-2G 26.78 36.0
CBS350-16P-2G 26.78 36.0
CBS350-16P-E-2G 26.78 36.0
CBS350-16FP-2G 26.78 36.0
CBS350-24T-4G 41.66 56.0
CBS350-24P-4G 41.66 56.0
CBS350-24FP-4G 41.66 56.0
CBS350-24S-4G 41.66 56.0
CBS350-48T-4G 77.38 104.0
CBS350-48P-4G 77.38 104.0
CBS350-48FP-4G 77.38 104.0
CBS350-24T-4X 95.23 128.0
CBS350-24P-4X 95.23 128.0
CBS350-24FP-4X 95.23 128.0
CBS350-48T-4X 130.94 176.0
CBS350-48P-4X 130.94 176.0
CBS350-48FP-4X 130.94 176.0
CBS350-8MGP-2X 46.13 62.0
CBS350-8MP-2X 29.76 80.0
CBS350-24MGP-4X 104.16 140.0
CBS350-12NP-4X 148.80 200.0
CBS350-24NGP-4X 142.85 192.0
CBS350-48NGP-4X 178.56 240.0
CBS350-8XT 119.05 160.0
CBS350-12XS 178.56 240.0
CBS350-12XT 178.56 240.0
CBS350-16XTS 238.08 320.0
CBS350-24XS 240.00 480.0
CBS350-24XT 240.00 480.0
CBS350-24XTS 240.00 480.0
CBS350-48XT-4X 755.81 1,040.0
Layer 2 Switching
Spanning Tree Protocol Standard 802.1d Spanning Tree support

Fast convergence using 802.1w (Rapid Spanning Tree [RSTP]), enabled by default

Multiple Spanning Tree instances using 802.1s (MSTP); 8 instances are supported

Per-VLAN Spanning Tree Plus (PVST+) and Rapid PVST+ (RPVST+); 126 instances are supported

Port grouping/link aggregation Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP)

Up to 8 groups

Up to 8 ports per group with 16 candidate ports for each (dynamic) 802.3ad link aggregation

VLAN Support for up to 4,094 VLANs simultaneously

Port-based and 802.1Q tag-based VLANs; MAC-based VLAN; protocol-based VLAN; IP subnet-based VLAN

Management VLAN

Private VLAN with promiscuous, isolated, and community port

Private VLAN Edge (PVE), also known as protected ports, with multiple uplinks

Guest VLAN, unauthenticated VLAN

Dynamic VLAN assignment via RADIUS server along with 802.1x client authentication

CPE VLAN

Voice VLAN Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoS. Voice Services Discovery Protocol (VSDP) delivers network wide zero-touch deployment of voice endpoints and call control devices
Multicast TV VLAN Multicast TV VLAN allows the single multicast VLAN to be shared in the network while subscribers remain in separate VLANs. This feature is also known as Multicast VLAN Registration (MVR)
VLAN Translation Support for VLAN One-to-One Mapping. In VLAN One-to-One Mapping, on an edge interface customer VLANs (C-VLANs) are mapped to service provider VLANs (S-VLANs) and the original C-VLAN tags are replaced by the specified S-VLAN
Q-in-Q VLANs transparently cross a service provider network while isolating traffic among customers
Selective Q-in-Q Selective Q-in-Q is an enhancement to the basic Q-in-Q feature and provides, per edge interface, multiple mappings of different C-VLANs to separate S-VLANs

Selective Q-in-Q also allows configuring of Ethertype (Tag Protocol Identifier [TPID]) of the S-VLAN tag

Layer 2 protocol tunneling over Q-in-Q is also supported

Generic VLAN Registration Protocol (GVRP)/Generic Attribute Registration Protocol (GARP) Generic VLAN Registration Protocol (GVRP) and Generic Attribute Registration Protocol (GARP) enable automatic propagation and configuration of VLANs in a bridged domain
Unidirectional Link Detection (UDLD) UDLD monitors physical connection to detect unidirectional links caused by incorrect wiring or cable/port faults to prevent forwarding loops and black holing of traffic in switched networks
Dynamic Host Configuration Protocol (DHCP) Relay at Layer 2 Relay of DHCP traffic to DHCP server in different VLAN; works with DHCP Option 82
Internet Group Management Protocol (IGMP) versions 1, 2, and 3 snooping IGMP limits bandwidth-intensive multicast traffic to only the requesters; supports 2K multicast groups (source-specific multicasting is also supported)
IGMP Querier IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router
IGMP proxy The IGMP proxy provides a mechanism for multicast forwarding based on IGMP membership information without the need for more complicated multicast routing protocols.
Head-of-Line (HOL) blocking HOL blocking prevention
Loopback Detection Loopback detection provides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STP
Layer 3
IPv4 routing Wirespeed routing of IPv4 packets

Up to 990 static routes and up to 128 IP interfaces

IPv6 routing Wirespeed routing of IPv6 packets
Layer 3 Interface Configuration of Layer 3 interface on physical port, Link Aggregation (LAG), VLAN interface, or loopback interface
Classless Interdomain Routing (CIDR) Support for classless interdomain routing
RIP v2 Support for Routing Information Protocol version 2 for dynamic routing
Policy-Based Routing (PBR) Flexible routing control to direct packets to different next hop based on IPv4 or IPv6 Access Control List (ACL)
DHCP Server Switch functions as an IPv4 DHCP server serving IP addresses for multiple DHCP pools/scopes

Support for DHCP options

DHCP relay at Layer 3 Relay of DHCP traffic across IP domains
User Datagram Protocol (UDP) relay Relay of broadcast information across Layer 3 domains for application discovery or relaying of Bootstrap Protocol (BOOTP)/DHCP packets
Stacking
Hardware stacking Up to 4 units in a stack. Up to 200 ports managed as a single system with hardware failover

Stacking is supported on the following models

CBS350-24T-4X, CBS350-24P-4X, CBS350-24FP-4X, CBS350-48T-4X, CBS350-48P-4X, CBS350-48FP-4X

CBS350-8MP-2X, CBS350-24MGP-4X, CBS350-12NP-4X, CBS350-24NGP-4X, CBS350-48NGP-4X

CBS350-8XT, CBS350-12XS, CBS350-12XT, CBS350-16XTS, CBS350-24XS, CBS350-24XT, CBS350-24XTS, CBS350-48XT-4X

High availability Fast stack failover delivers minimal traffic loss. Support link aggregation across multiple units in a stack
Plug-and-play stacking configuration/management Active/standby for resilient stack control

Autonumbering

Hot swap of units in stack

Ring and chain stacking options, auto stacking port speed, flexible stacking port options

High-speed stack interconnects Cost-effective high-speed 10G fiber interfaces.
Security
Secure Shell (SSH) Protocol SSH is a secure replacement for Telnet traffic. Secure Copy Protocol (SCP) also uses SSH. SSH v1 and v2 are supported
Secure Sockets Layer (SSL) SSL support : Encrypts all HTTPS traffic, allowing highly secure access to the browser-based management GUI in the switch
IEEE 802.1X (Authenticator role) 802.1X : Remote Authentication Dial-In User Service (RADIUS) authentication and accounting, MD5 hash; guest VLAN; unauthenticated VLAN, single/multiple host mode and single/multiple sessions

Supports time-based 802.1X; dynamic VLAN assignment; MAC authentication

IEEE 802.1X supplicant A switch can be configured to act as a supplicant to another switch. This enables extended secure access in areas outside the wiring closet (such as conference rooms)
Web-based authentication Web-based authentication provides network admission control through web browser to any host devices and operating systems
STP Bridge Protocol Data Unit (BPDU) Guard A security mechanism to protect the network from invalid configurations. A port enabled for BPDU Guard is shut down if a BPDU message is received on that port. This avoids accidental topology loops
STP Root Guard This prevents edge devices not in the network administrator’s control from becoming Spanning Tree Protocol root nodes
STP loopback guard Provides additional protection against Layer 2 forwarding loops (STP loops)
DHCP snooping Filters out DHCP messages with unregistered IP addresses and/or from unexpected or untrusted interfaces. This prevents rogue devices from behaving as DHCP Servers.
IP Source Guard (IPSG) When IP Source Guard is enabled at a port, the switch filters out IP packets received from the port if the source IP addresses of the packets have not been statically configured or dynamically learned from DHCP snooping. This prevents IP address spoofing.
Dynamic ARP Inspection (DAI) The switch discards ARP packets from a port if there are no static or dynamic IP/MAC bindings or if there is a discrepancy between the source or destination addresses in the ARP packet. This prevents man-in-the-middle attacks.
IP/MAC/Port Binding (IPMB) The preceding features (DHCP Snooping, IP Source Guard, and Dynamic ARP Inspection) work together to prevent DOS attacks in the network, thereby increasing network availability
Secure Core Technology (SCT) Makes sure that the switch will receive and process management and protocol traffic no matter how much traffic is received
Secure Sensitive Data (SSD) A mechanism to manage sensitive data (such as passwords, keys, and so on) securely on the switch, populating this data to other devices, and secure autoconfig. Access to view the sensitive data as plaintext or encrypted is provided according to the user-configured access level and the access method of the user.
Trustworthy systems Trustworthy systems provide a highly secure foundation for Cisco products

Run-time defenses (Executable Space Protection [X-Space], Address Space Layout Randomization [ASLR], Built-In Object Size Checking [BOSC])

Private VLAN Private VLAN provides security and isolation between switch ports, which helps ensure that users cannot snoop on other users’ traffic; supports multiple uplinks
Layer 2 isolation Private VLAN Edge (PVE) PVE (also known as protected ports) provides Layer 2 isolation between devices in the same VLAN, supports multiple uplinks
Port security Ability to lock source MAC addresses to ports and limits the number of learned MAC addresses
RADIUS/TACACS+ Supports RADIUS and TACACS authentication. Switch functions as a client
RADIUS accounting The RADIUS accounting functions allow data to be sent at the start and end of services, indicating the amount of resources (such as time, packets, bytes, and so on) used during the session
Storm control Broadcast, multicast, and unknown unicast
DoS prevention Denial-of-Service (DOS) attack prevention
Multiple user privilege levels in CLI Level 1, 7, and 15 privilege levels
ACLs Support for up to 1,024 rules

Drop or rate limit based on source and destination MAC, VLAN ID, IPv4 or IPv6 address, IPv6 flow label, protocol, port, Differentiated Services Code Point (DSCP)/IP precedence, Transmission Control Protocol/User Datagram Protocol (TCP/UDP) source and destination ports, 802.1p priority, Ethernet type, Internet Control Message Protocol (ICMP) packets, IGMP packets, TCP flag; ACL can be applied on both ingress and egress sides

Time-based ACLs supported

Quality of Service
Priority levels 8 hardware queues
Scheduling Strict priority and Weighted Round-Robin (WRR)
Class of service Port based; 802.1p VLAN priority-based; IPv4/v6 IP precedence/Type of Service (ToS)/DSCP-based; Differentiated Services (DiffServ); classification and remarking ACLs, trusted QoS

Queue assignment based on DSCP and class of service (802.1p/CoS)

Rate limiting Ingress policer; egress shaping and rate control; per VLAN, per port, and flow based; 2R3C policing
Congestion avoidance A TCP congestion avoidance algorithm is required to minimize and prevent global TCP loss synchronization
iSCSI traffic optimization A mechanism for giving priority to iSCSI traffic over other types of traffic
Standards
Standards IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3ae 10 Gbit/s Ethernet over fiber for LAN, IEEE 802.3an 10GBase-T 10 Gbit/s Ethernet over copper twisted pair cable, IEEE 802.3x Flow Control, IEEE 802.1D (STP, GARP, and GVRP), IEEE 802.1Q/p VLAN, IEEE 802.1w Rapid STP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, IEEE 802.1AB Link Layer Discovery Protocol, IEEE 802.3az Energy Efficient Ethernet, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793, RFC 813, RFC 826, RFC 879, RFC 896, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC 919, RFC 920, RFC 922, RFC 950, RFC 951, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1213, RFC 1215, RFC 1286, RFC 1350, RFC 1442, RFC 1451, RFC 1493, RFC 1533, RFC 1541, RFC 1542, RFC 1573, RFC 1624, RFC 1643, RFC 1700, RFC 1757, RFC 1867, RFC 1907, RFC 2011, RFC 2012, RFC 2013, RFC 2030, RFC 2131, RFC 2132, RFC 2233, RFC 2576, RFC 2616, RFC 2618, RFC 2665, RFC 2666, RFC 2674, RFC 2737, RFC 2819, RFC 2863, RFC 3164, RFC 3176, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 3416, RFC 4330
IPv6
IPv6 IPv6 host mode; IPv6 over Ethernet; Dual IPv6/IPv4 stack

IPv6 neighbor and router discovery (ND); IPv6 stateless address autoconfiguration; Path Maximum Transmission Unit (MTU) discovery

Duplicate Address Detection (DAD); ICMP version 6

DHCPv6 stateful client

IPv6 over IPv4 network with Intrasite Automatic Tunnel Addressing Protocol (ISATAP) tunnel support

USGv6 and IPv6 Gold Logo certified

IPv6 QoS Prioritize IPv6 packets in hardware
IPv6 ACL Drop or rate limit IPv6 packets in hardware
IPv6 First Hop Security RA guard

ND inspection

DHCPv6 guard

Neighbor binding table (snooping and static entries)

Neighbor binding integrity check

Multicast Listener Discovery (MLD v1/2) snooping Deliver IPv6 multicast packets only to the required receivers
MLD proxy The MLD proxy provides a mechanism for multicast forwarding based on MLD membership information without the need for more complicated multicast routing protocols.
IPv6 applications Web/SSL, Telnet server/SSH, ping, traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), SNMP, RADIUS, syslog, Domain Name System (DNS) client, Telnet Client, DHCP Client, DHCP Autoconfig, IPv6 DHCP Relay, Terminal Access Controller Access Control System Plus (TACACS+)
IPv6 RFCs supported RFC 4443 (which obsoletes RFC2463) : ICMP version 6

RFC 4291 (which obsoletes RFC 3513) : IPv6 address architecture

RFC 4291 : IPv6 addressing architecture

RFC 2460 : IPv6 specification

RFC 4861 (which obsoletes RFC 2461) : neighbor discovery for IPv6

RFC 4862 (which obsoletes RFC 2462) : IPv6 stateless address autoconfiguration

RFC 1981 : path MTU discovery

RFC 4007 : IPv6 scoped address architecture

RFC 3484 : default address selection mechanism

RFC 5214 (which obsoletes RFC 4214) : ISATAP tunneling

RFC 4293 : MIB IPv6 : textual conventions and general group

RFC 3595 : textual conventions for IPv6 flow label

Management
Cisco Business Dashboard Support for embedded probe for Cisco Business Dashboard running on the switch. Eliminates the need to set up a separate hardware or virtual machine for the Cisco Business Dashboard Probe on site.
Cisco Business mobile app Mobile app for Cisco Business Switch and Wireless products. Helps to set up a local network in minutes and provide easy management at your fingertips.
Cisco Network Plug and Play (PnP) agent The Cisco Network Plug and Play solution provides a simple, secure, unified, and integrated offering to ease new branch or campus device rollouts or for provisioning updates to an existing network. The solution provides a unified approach to provision Cisco routers, switches, and wireless devices with a near-zero-touch deployment experience

Supports Cisco PnP Connect

Web user interface Built-in switch configuration utility for easy browser-based device configuration (HTTP/HTTPS).

Supports simple and advanced mode, configuration, wizards, customizable dashboard, system maintenance, monitoring, online help, and universal search

SNMP SNMP versions 1, 2c, and 3 with support for traps, and SNMP version 3 User-based Security Model (USM)
Standard Management Information Bases (MIBs) lldp-MIB

lldpextdot1-MIB

lldpextdot3-MIB

lldpextmed-MIB

rfc2674-MIB

rfc2575-MIB

rfc2573-MIB

rfc2233-MIB

rfc2013-MIB

rfc2012-MIB

rfc2011-MIB

RFC-1212

RFC-1215

SNMPv2-CONF

SNMPv2-TC

p-bridge-MIB

q-bridge-MIB

rfc1389-MIB

rfc1493-MIB

rfc1611-MIB

rfc1612-MIB

rfc1850-MIB

rfc1907-MIB

rfc2571-MIB

rfc2572-MIB

rfc2574-MIB

rfc2576-MIB

rfc2613-MIB

rfc2665-MIB

rfc2668-MIB

rfc2737-MIB

rfc2925-MIB

rfc3621-MIB

rfc4668-MIB

rfc4670-MIB

trunk-MIB

tunnel-MIB

udp-MIB

draft-ietf-bridge-8021x-MIB

draft-ietf-bridge-rstpmib-04-MIB

draft-ietf-hubmib-etherif-mib-v3-00-MIB

draft-ietf-syslog-device-MIB

ianaaddrfamnumbers-MIB

ianaifty-MIB

ianaprot-MIB

inet-address-MIB

ip-forward-MIB

ip-MIB

RFC1155-SMI

RFC1213-MIB

SNMPv2-MIB

SNMPv2-SMI

SNMPv2-TM

RMON-MIB

rfc1724-MIB

dcb-raj-DCBX-MIB-1108-MIB

rfc1213-MIB

rfc1757-MIB

Private MIBs CISCOSB-lldp-MIB

CISCOSB-brgmulticast-MIB

CISCOSB-bridgemibobjects-MIB

CISCOSB-bonjour-MIB

CISCOSB-dhcpcl-MIB

CISCOSB-MIB

CISCOSB-wrandomtaildrop-MIB

CISCOSB-traceroute-MIB

CISCOSB-telnet-MIB

CISCOSB-stormctrl-MIB

CISCOSB-ssh-MIB

CISCOSB-socket-MIB

CISCOSB-sntp-MIB

CISCOSB-smon-MIB

CISCOSB-phy-MIB

CISCOSB-multisessionterminal-MIB

CISCOSB-mri-MIB

CISCOSB-jumboframes-MIB

CISCOSB-gvrp-MIB

CISCOSB-endofmib-MIB

CISCOSB-dot1x-MIB

CISCOSB-deviceparams-MIB

CISCOSB-cli-MIB

CISCOSB-cdb-MIB

CISCOSB-brgmacswitch-MIB

CISCOSB-3sw2swtables-MIB

CISCOSB-smartPorts-MIB

CISCOSB-tbi-MIB

CISCOSB-macbaseprio-MIB

CISCOSB-policy-MIB

CISCOSB-env_mib

CISCOSB-sensor-MIB

CISCOSB-aaa-MIB

CISCOSB-application-MIB

CISCOSB-bridgesecurity-MIB

CISCOSB-copy-MIB

CISCOSB-CpuCounters-MIB

CISCOSB-Custom1BonjourService-MIB

CISCOSB‑dhcp-MIB

CISCOSB-dlf-MIB

CISCOSB-dnscl-MIB

CISCOSB-embweb-MIB

CISCOSB-fft-MIB

CISCOSB-file-MIB

CISCOSB-greeneth-MIB

CISCOSB-interfaces-MIB

CISCOSB-interfaces_recovery-MIB

CISCOSB-ip-MIB

CISCOSB-iprouter-MIB

CISCOSB-ipv6-MIB

CISCOSB-mnginf-MIB

CISCOSB-lcli-MIB

CISCOSB-localization-MIB

CISCOSB-mcmngr-MIB

CISCOSB-mng-MIB

CISCOSB-physdescription-MIB

CISCOSB-PoE-MIB

CISCOSB-protectedport-MIB

CISCOSB-rmon-MIB

CISCOSB-rs232-MIB

CISCOSB-SecuritySuite-MIB

CISCOSB-snmp-MIB

CISCOSB-specialbpdu-MIB

CISCOSB-banner-MIB

CISCOSB-syslog-MIB

CISCOSB-TcpSession-MIB

CISCOSB-traps-MIB

CISCOSB-trunk-MIB

CISCOSB-tuning-MIB

CISCOSB-tunnel-MIB

CISCOSB-udp-MIB

CISCOSB-vlan-MIB

CISCOSB-ipstdacl-MIB

CISCOSB-eee-MIB

CISCOSB-ssl-MIB

CISCOSB-qosclimib-MIB

CISCOSB-digitalkeymanage-MIB

CISCOSB-tbp-MIB

CISCOSMB-MIB

CISCOSB-secsd-MIB

CISCOSB-draft-ietf-entmib-sensor-MIB

CISCOSB-draft-ietf-syslog-device-MIB

CISCOSB-rfc2925-MIB

CISCO-SMI-MIB

CISCOSB-DebugCapabilities-MIB

CISCOSB-CDP-MIB

CISCOSB-vlanVoice-MIB

CISCOSB-EVENTS-MIB

CISCOSB-sysmng-MIB

CISCOSB-sct-MIB

CISCO-TC-MIB

CISCO-VTP-MIB

CISCO-CDP-MIB

 

Remote Monitoring (RMON) Embedded RMON software agent supports 4 RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis
IPv4 and IPv6 dual stack Coexistence of both protocol stacks to ease migration
Firmware upgrade Web browser upgrade (HTTP/HTTPS) and TFTP and upgrade over SCP running over SSH

Dual images for resilient firmware upgrades

Port mirroring Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe. Up to 8 source ports can be mirrored to one destination port.
VLAN mirroring Traffic from a VLAN can be mirrored to a port for analysis with a network analyzer or RMON probe. Up to 8 source VLANs can be mirrored to one destination port.
Flow-based redirection and mirroring Redirect or mirror traffic to a destination port or mirroring session based on flow
Remote Switch Port Analyzer (RSPAN) Traffic can be mirrored across Layer 2 domain to a remote port on a different switch for easier troubleshooting
sFlow agent Switch can export sFlow sample to external collectors. sFlow provides visibility into network traffic down to flow level
DHCP (options 12, 59, 60, 66, 67, 82, 125, 129, and 150) DHCP options facilitate tighter control from a central point (DHCP server) to obtain IP address, autoconfiguration (with configuration and image file download), DHCP relay, and hostname
Secure Copy (SCP) Securely transfer files to and from the switch
Autoconfiguration with Secure Copy (SCP) file download Enables secure mass deployment with protection of sensitive data
Text-editable config files Config files can be edited with a text editor and downloaded to another switch, facilitating easier mass deployment
Smartports Simplified configuration of QoS and security capabilities
Auto Smartports Applies the intelligence delivered through the Smartport roles and applies it automatically to the port based on the devices discovered over Cisco Discovery Protocol or LLDP-MED. This facilitates zero-touch deployments
Textview CLI Scriptable command-line interface. A full CLI as well as a menu-based CLI is supported. User privilege levels 1, 7, and 15 are supported for the CLI
Localization Localization of GUI and documentation into multiple languages
Login banner Configurable multiple banners for web as well as CLI
Other management Traceroute; single IP management; HTTP/HTTPS; SSH; RADIUS; port mirroring; TFTP upgrade; DHCP client; BOOTP; SNTP; Xmodem upgrade; cable diagnostics; ping; syslog; Telnet client (SSH secure support); automatic time settings from Management Station
Green (power efficiency)
Energy Detect Automatically turns power off on RJ-45 port when detecting link down. Active mode is resumed without loss of any packets when the switch detects the link up
Cable length detection Adjusts the signal strength based on the cable length. Reduces the power consumption for shorter cables.
EEE Compliant (802.3az) Supports IEEE 802.3az on all copper Gigabit Ethernet ports
Disable port LEDs LEDs can be manually turned off to save on energy
Time-based port operation Link up or down based on user-defined schedule (when the port is administratively up)
Time-based PoE PoE power can be on or off based on user-defined schedule to save energy
General
Jumbo frames Frame sizes up to 9K bytes. The default MTU is 2K bytes
MAC table 16K addresses
Discovery
Bonjour The switch advertises itself using the Bonjour protocol
Link Layer Discovery Protocol (LLDP) (802.1ab) with LLDP‑MED extensions LLDP allows the switch to advertise its identification, configuration, and capabilities to neighboring devices that store the data in a MIB. LLDP-MED is an enhancement to LLDP that adds the extensions needed for IP phones
Cisco Discovery Protocol The switch advertises itself using the Cisco Discovery Protocol. It also learns the connected device and its characteristics via Cisco Discovery Protocol
Power over Ethernet (PoE)
802.3af PoE, 802.3at PoE+ or 60W PoE delivered over the RJ-45 ports within the listed power budgets The following switches support 802.3at PoE+, 802.3af, and Cisco prestandard (legacy) PoE. 60W PoE is also supported on select RJ-45 network ports on select models. The total power available for PoE per switch is as follows :
Model Name Power Dedicated to PoE Number of Ports That Support PoE
CBS350-8P-2G 67W 8
CBS350-8P-E-2G 60W 8
CBS350-8FP-2G 120W 8
CBS350-8FP-E-2G 120W 8
CBS350-16P-2G 120W 16
CBS350-16P-E-2G 120W 16
CBS350-16FP-2G 240W 16
CBS350-24P-4G 195W 24
CBS350-24FP-4G 370W 24
CBS350-48P-4G 370W 48
CBS350-48FP-4G 740W 48
CBS350-24P-4X 195W 24
CBS350-24FP-4X 370W 24
CBS350-48P-4X 370W 48
CBS350-48FP-4X 740W 48
CBS350-8MGP-2X 124W 8
CBS350-8MP-2X 240W 8 (4 support 60W PoE)
CBS350-24MGP-4X 375W 24 (4 support 60W PoE)
CBS350-12NP-4X 375W 12 (8 support 60W PoE)
CBS350-24NGP-4X 375W 24 (8 support 60W PoE)
CBS350-48NGP-4X 740W 48 (8 support 60W PoE)
Hardware
Power consumption
(worst case)
Model System Power Consumption Power Consumption (with PoE) Heat Dissipation (BTU/hr)
CBS350-8T-E-2G 110V=12.55W

220V=12.56W

N/A 42.86
CBS350-8P-2G 110V=17.35W

220V=17.95W

110V=83.17W

220V=82.63W

283.79
CBS350-8P-E-2G 110V=13.84W

220V=14.31W

110V=80.79W

220V=80.86W

275.91
CBS350-8FP-2G 110V=17.29W

220V=17.88W

110V=148.12W

220V=146.36W

505.41
CBS350-8FP-E-2G 110V=17.07W

220V=16.68W

110V=147.48W

220V=145.26W

503.22
CBS350-8S-E-2G 110V=11.1W

220V=11.9W

N/A 40.6
CBS350-16T-2G 110V=18.63W

220V=18.37W

N/A 64.46
CBS350-16T-E-2G 110V=19.63W

220V=19.32W

N/A 65.92
CBS350-16P-2G 110V=24.51W

220V=25.01W

110V=156.4W

220V=154.5W

536.39
CBS350-16P-E-2G 110V=23.65W

220V=23.68W

110V=150.1W

220V=148.8W

512.16
CBS350-16FP-2G 110V=27.53W

220V=26.68W

110V=284W

220V=279.8W

971.78
CBS350-24T-4G 110V=25.91W

220V=25.63W

N/A 89.13
CBS350-24P-4G 110V=34.42W

220V=33.09W

110V=239.7W

220V=236.4W

820.62
CBS350-24FP-4G 110V=46.60W

220V=46.35W

110V=449.7W

220V=438.3W

1,537.17
CBS350-24S-4G 110V=32.0W

220V=34.3W

N/A 117.0
CBS350-48T-4G 110V=48.27W

220V=48.64W

N/A 165.96
CBS350-48P-4G 110V=60.77W

220V=59.73W

110V=451.95W

220V=445.85W

1,542.12
CBS350-48FP-4G 110V=73.79W

220V=74.03W

110V=886.42W

220V=859.50W

3,024.59
CBS350-24T-4X 110V=27.54W

220V=27.25W

N/A 93.32
CBS350-24P-4X 110V=35.72W

220V=34.53W

110V=240.4W

220V=236.9W

823.01
CBS350-24FP-4X 110V=47.14W

220V=47.01W

110V=451.8W

220V=437.4W

1,544.34
CBS350-48T-4X 110V=51.01W

220V=50.58W

N/A 174.06
CBS350-48P-4X 110V=61.53W

220V=60.73W

110V=471.90W

220V=463.32W

1,610.19
CBS350-48FP-4X 110V=76.18W

220V=76.22W

110V=889.35W

220V=865.02W

3,034.59
CBS350-8MGP-2X 110V=29.8W

220V=31.3W

110V=167W

220V=165.2W

569.5
CBS350-8MP-2X 110V=48.4W

220V=50.5W

110V=312.4W

220V=307.3W

1,065.9
CBS350-24MGP-4X 110V=64.3W

220V=64.8W

110V=476.6W

220V=450.6W

1,626.2
CBS350-12NP-4X 110V=59.8W

220V=60.1W

110V=494.5W

220V=476.4W

1,687.3
CBS350-24NGP-4X 110V=56.9W

220V=56.6W

110V=488.9W

220V=474.5W

1,668.2
CBS350-48NGP-4X 110V=94.1W

220V=93.7W

110V=916W

220V=914.4W

3,125.5
CBS350-8XT 110V=50.3W

220V=50.3W

N/A 171.6
CBS350-12XS 110V=24.3W

220V=25.3W

N/A 86.33
CBS350-12XT 110V=63.9W

220V=64.1W

N/A 218.7
CBS350-16XTS 110V=57W

220V=57.7W

N/A 196.88
CBS350-24XS 110V=38.5W

220V=39.0W

N/A 133.1
CBS350-24XT 110V=124.1W

220V=124.5W

N/A 424.8
CBS350-24XTS 110V=78.4W

220V=80.2W

N/A 273.65
CBS350-48XT-4X 110V=234.4W

220V=229.2W

N/A 799.8
Ports Model Name Total System Ports RJ-45 Ports Combo Ports (RJ45 + Small form-factor pluggable [SFP])
CBS350-8T-E-2G 10 x Gigabit Ethernet 8 x Gigabit Ethernet 2 x Gigabit Ethernet combo
CBS350-8P-2G 10 x Gigabit Ethernet 8 x Gigabit Ethernet 2 x Gigabit Ethernet combo
CBS350-8P-E-2G 10 x Gigabit Ethernet 8 x Gigabit Ethernet 2 x Gigabit Ethernet combo
CBS350-8FP-2G 10 x Gigabit Ethernet 8 x Gigabit Ethernet 2 x Gigabit Ethernet combo
CBS350-8FP-E-2G 10 x Gigabit Ethernet 8 x Gigabit Ethernet 2 x Gigabit Ethernet combo
CBS350-8S-E-2G 10 x Gigabit Ethernet 8 x Gigabit SFP Slots 2 x Gigabit Ethernet combo
CBS350-16T-2G 18 x Gigabit Ethernet 16 x Gigabit Ethernet 2 x SFP
CBS350-16T-E-2G 18 x Gigabit Ethernet 16 x Gigabit Ethernet 2 x SFP
CBS350-16P-2G 18 x Gigabit Ethernet 16 x Gigabit Ethernet 2 x SFP
CBS350-16P-E-2G 18 x Gigabit Ethernet 16 x Gigabit Ethernet 2 x SFP
CBS350-16FP-2G 18 x Gigabit Ethernet 16 x Gigabit Ethernet 2 x SFP
CBS350-24T-4G 28 x Gigabit Ethernet 24 x Gigabit Ethernet 4 x SFP
CBS350-24P-4G 28 x Gigabit Ethernet 24 x Gigabit Ethernet 4 x SFP
CBS350-24FP-4G 28 x Gigabit Ethernet 24 x Gigabit Ethernet 4 x SFP
CBS350-24S-4G 28 x Gigabit Ethernet 24 x Gigabit SFP Slots 2 x Gigabit Ethernet combo + 2 SFP
CBS350-48T-4G 52 x Gigabit Ethernet 48 x Gigabit Ethernet 4 x SFP
CBS350-48P-4G 52 x Gigabit Ethernet 48 x Gigabit Ethernet 4 x SFP
CBS350-48FP-4G 52 x Gigabit Ethernet 48 x Gigabit Ethernet 4 x SFP
CBS350-24T-4X 24 x Gigabit Ethernet + 4 x 10G 24 x Gigabit Ethernet 4 x SFP+
CBS350-24P-4X 24 x Gigabit Ethernet + 4 x 10G 24 x Gigabit Ethernet 4 x SFP+
CBS350-24FP-4X 24 Gigabit Ethernet +
4 x 10G
24 x Gigabit Ethernet 4 x SFP+
CBS350-48T-4X 48 Gigabit Ethernet +
4 x 10G
48 x Gigabit Ethernet 4 x SFP+
CBS350-48P-4X 48 Gigabit Ethernet +
4 x 10G
48 x Gigabit Ethernet 4 x SFP+
CBS350-48FP-4X 48 Gigabit Ethernet +
4 x 10G
48 x Gigabit Ethernet 4 x SFP+
CBS350-8MGP-2X 6 x Gigabit Ethernet + 2 x 2.5G + 2 x Multigigabit 6 x Gigabit Ethernet + 2 x 2.5G 2 x Multigigabit/SFP+ combo
CBS350-8MP-2X 8 x 2.5G + 2 x 10G 8 x 2.5G 2 x 10G copper/SFP+ combo
CBS350-24MGP-4X 20 x Gigabit Ethernet + 4 x 2.5G + 4 x 10G 20 x Gigabit Ethernet + 4 x 2.5G 2 x 10G copper/SFP+ combo + 2 SFP+
CBS350-12NP-4X 12 x 5G + 4 x 10G 12 x 5G 2 x 10G copper/SFP+ combo + 2 SFP+
CBS350-24NGP-4X 16 x Gigabit Ethernet + 8 x 5G + 4 x 10G 16 x Gigabit Ethernet + 8 x 5G 2 x 10G copper/SFP+ combo + 2 SFP+
CBS350-48NGP-4X 40 x Gigabit Ethernet + 8 x 5G + 4 x 10G 40 x Gigabit Ethernet + 8 x 5G 2 x 10G copper/SFP+ combo + 2 SFP+
CBS350-8XT 6 x 10G copper + 2 x 10G copper/SFP+ combo + 1 x GE OOB management 6 x 10G copper 2 x 10G copper/SFP+ combo
CBS350-12XS 10 x 10G SFP+ + 2 x 10G copper/SFP+ combo + 1 x GE OOB management 10 x 10G SFP+ 2 x 10G copper/SFP+ combo
CBS350-12XT 10 x 10G copper + 2 x 10G copper/SFP+ combo + 1 x GE OOB management 10 x 10G copper 2 x 10G copper/SFP+ combo
CBS350-16XTS 8 x 10G copper + 8 x 10G SFP+ + 1 x GE OOB management 8 x 10G copper 8 x 10G SFP+
CBS350-24XS 20 x 10G SFP+ + 4 x 10G copper/SFP+ combo + 1 x GE OOB management 20 x 10G SFP+ 4 x 10G copper/SFP+ combo
CBS350-24XT 20 x 10G copper + 4 x 10G copper/SFP+ combo + 1 x GE OOB management 20 x 10G copper 4 x 10G copper/SFP+ combo
CBS350-24XTS 12 x 10G copper + 12 x 10G SFP+ + 1 x GE OOB management 12 x 10G copper 12 x 10G SFP+
CBS350-48XT-4X 48 x 10G copper + 4 x 10G SFP+ + 1 x GE OOB management 48 x 10G copper 4 x 10G SFP+
Console port Cisco standard mini USB Type-B/RJ45 console port

CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G, CBS350-16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G, CBS350-24T-4X, CBS350-24P-4X, CBS350-24FP-4X, CBS350-48T-4X, CBS350-48P-4X, CBS350-48FP-4X

Cisco standard RJ45 console port

CBS350-8S-E-2G, CBS350-24S-4G, CBS350-8MGP-2X, CBS350-8MP-2X, CBS350-24MGP-4X, CBS350-12NP-4X, CBS350-24NGP-4X, CBS350-48NGP-4X, CBS350-8XT, CBS350-12XS, CBS350-12XT, CBS350-16XTS, CBS350-24XS, CBS350-24XT, CBS350-24XTS, CBS350-48XT-4X

USB slot USB Type-A slot on the front panel of the switch for easy file and image management
Buttons Reset button
Cabling type Unshielded Twisted Pair (UTP) Category 5e or better for 1000BASE-T
LEDs System, Link/Act, PoE, Speed
Flash 256 MB
CPU 800 MHz ARM
DRAM 512 MB
Packet buffer All numbers are aggregate across all ports as the buffers are dynamically shared :
Model Name Packet Buffer
CBS350-8T-E-2G 1.5 MB
CBS350-8P-2G 1.5 MB
CBS350-8P-E-2G 1.5 MB
CBS350-8FP-2G 1.5 MB
CBS350-8FP-E-2G 1.5 MB
CBS350-8S-E-2G 1.5 MB
CBS350-16T-2G 1.5 MB
CBS350-16T-E-2G 1.5 MB
CBS350-16P-2G 1.5 MB
CBS350-16P-E-2G 1.5 MB
CBS350-16FP-2G 1.5 MB
CBS350-24T-4G 1.5 MB
CBS350-24P-4G 1.5 MB
CBS350-24FP-4G 1.5 MB
CBS350-24S-4G 1.5 MB
CBS350-48T-4G 3 MB
CBS350-48P-4G 3 MB
CBS350-48FP-4G 3 MB
CBS350-24T-4X 1.5 MB
CBS350-24P-4X 1.5 MB
CBS350-24FP-4X 1.5 MB
CBS350-48T-4X 3 MB
CBS350-48P-4X 3 MB
CBS350-48FP-4X 3 MB
CBS350-8MGP-2X 1.5 MB
CBS350-8MP-2X 1.5 MB
CBS350-24MGP-4X 3 MB
CBS350-12NP-4X 3 MB
CBS350-24NGP-4X 3 MB
CBS350-48NGP-4X 6 MB
CBS350-8XT 6 MB
CBS350-12XS 3 MB
CBS350-12XT 3 MB
CBS350-16XTS 3 MB
CBS350-24XS 3 MB
CBS350-24XT 3 MB
CBS350-24XTS 3 MB
CBS350-48XT-4X 10 MB
Supported SFP modules SKU Media Speed Maximum Distance
MGBSX1 Multimode fiber 1000 Mbps 500 m
MGBLX1 Single-mode fiber 1000 Mbps 10 km
MGBLH1 Single-mode fiber 1000 Mbps 40 km
MGBT1 UTP cat 5e 1000 Mbps 100 m
GLC-SX-MMD Multimode fiber 1000 Mbps 550 m
GLC-LH-SMD Single-mode fiber 1000 Mbps 10 km
GLC-BX-U Single-mode fiber 1000 Mbps 10 km
GLC-BX-D Single-mode fiber 1000 Mbps 10 km
GLC-TE UTP cat 5e 1000 Mbps 100 m
SFP-H10GB-CU1M Copper coax 10 Gig 1 m
SFP-H10GB-CU3M Copper coax 10 Gig 3 m
SFP-H10GB-CU5M Copper coax 10 Gig 5 m
SFP-10G-SR Multimode fiber 10 Gig 26 m – 400 m
SFP-10G-LR Single-mode fiber 10 Gig 10 km
SFP-10G-SR-S Multimode fiber 10 Gig 26 m – 400 m
SFP-10G-LR-S Single-mode fiber 10 Gig 10 km
Environmental
Unit dimensions
(W x D x H)
Model Name Unit Dimensions
CBS350-8T-E-2G 268 x 185 x 44 mm (10.56 x 7.28 x 1.73 in)
CBS350-8P-2G 268 x 272 x 44 mm (10.56 x 10.71 x 1.73 in)
CBS350-8P-E-2G 268 x 185 x 44 mm (10.56 x 7.28 x 1.73 in)
CBS350-8FP-2G 268 x 272 x 44 mm (10.56 x 10.71 x 1.73 in)
CBS350-8FP-E-2G 268 x 185 x 44 mm (10.56 x 7.28 x 1.73 in)
CBS350-8S-E-2G 280 x 170 x 44 mm (11.0 x 6.69 x 1.73 in)
CBS350-16T-2G 268 x 272 x 44 mm (10.56 x 10.69 x 1.73 in)
CBS350-16T-E-2G 268 x 210 x 44 mm (10.56 x 8.26 x 1.73 in)
CBS350-16P-2G 268 x 297 x 44 mm (10.56 x 11.69 x 1.73 in)
CBS350-16P-E-2G 268 x 210 x 44 mm (10.56 x 8.26x 1.73 in)
CBS350-16FP-2G 268 x 308 x 44 mm (10.56 x 12.14 x 1.73 in)
CBS350-24T-4G 445 x 240 x 44 mm (17.5 x 9.45 x 1.73 in)
CBS350-24P-4G 445 x 299 x 44 mm (17.5 x 11.77 x 1.73 in)
CBS350-24FP-4G 445 x 345 x 44 mm (17.5 x 13.59 x 1.73 in)
CBS350-24S-4G 440 x 203 x 44 mm (17.3 x 7.99 x 1.73 in)
CBS350-48T-4G 445 x 288 x 44 mm (17.5 x 11.33 x 1.73 in)
CBS350-48P-4G 445 x 350 x 44 mm (17.5 x 13.78 x 1.73 in)
CBS350-48FP-4G 445 x 350 x 44 mm (17.5 x 13.78 x 1.73 in)
CBS350-24T-4X 445 x 240 x 44 mm (17.5 x 9.45 x 1.73 in)
CBS350-24P-4X 445 x 299 x 44 mm (17.5 x 11.77 x 1.73 in)
CBS350-24FP-4X 445 x 345 x 44 mm (17.5 x 13.59 x 1.73 in)
CBS350-48T-4X 445 x 288 x 44 mm (17.5 x 11.33 x 1.73 in)
CBS350-48P-4X 445 x 350 x 44 mm (17.5 x 13.78 x 1.73 in)
CBS350-48FP-4X 445 x 350 x 44 mm (17.5 x 13.78 x 1.73 in)
CBS350-8MGP-2X 344 x 252 x 44 mm (13.6 x 9.94 x 1.73 in)
CBS350-8MP-2X 344 x 252 x 44 mm (13.6 x 9.94 x 1.73 in)
CBS350-24MGP-4X 440 x 257 x 44 mm (17.3 x 10.12 x 1.73 in)
CBS350-12NP-4X 440 x 257 x 44 mm (17.3 x 10.12 x 1.73 in)
CBS350-24NGP-4X 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in)
CBS350-48NGP-4X 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in)
CBS350-8XT 440 x 203 x 44 mm (17.3 x 8.0 x 1.73 in)
CBS350-12XS 440 x 257 x 44 mm (17.3 x 10.12 x 1.73 in)
CBS350-12XT 440 x 203 x 44 mm (17.3 x 8.0 x 1.73 in)
CBS350-16XTS 440 x 257 x 44 mm (17.3 x 10.12 x 1.73 in)
CBS350-24XS 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in)
CBS350-24XT 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in)
CBS350-24XTS 440 x 350 x 44 mm (17.3 x 13.78 x 1.73 in)
CBS350-48XT-4X 440 x 450 x 44 mm (17.3 x 17.72 x 1.73 in)
Unit weight Model Name Unit Weight
CBS350-8T-E-2G 1.39 kg (3.06 lb)
CBS350-8P-2G 2.59 kg (5.71 lb)
CBS350-8P-E-2G 1.53 kg (3.37 lb)
CBS350-8FP-2G 2.59 kg (5.71 lb)
CBS350-8FP-E-2G 1.53 kg (3.37 lb)
CBS350-8S-E-2G 1.0 kg (2.20 lb)
CBS350-16T-2G 1.78 kg (3.92 lb)
CBS350-16T-E-2G 1.42 kg (3.13 lb)
CBS350-16P-2G 2.38 kg (5.25 lb)
CBS350-16P-E-2G 1.42 kg (3.13 lb)
CBS350-16FP-2G 2.49 kg (5.49 lb)
CBS350-24T-4G 2.63 kg (5.80 lb)
CBS350-24P-4G 3.53 kg (7.78 lb)
CBS350-24FP-4G 4.6 kg (10.14 lb)
CBS350-24S-4G 2.7 kg (5.95 lb)
CBS350-48T-4G 3.95 kg (8.71 lb)
CBS350-48P-4G 5.43 kg (11.97 lb)
CBS350-48FP-4G 5.82 kg (12.83 lb)
CBS350-24T-4X 2.78 kg (6.13 lb)
CBS350-24P-4X 3.68 kg (8.11 lb)
CBS350-24FP-4X 4.6 kg (10.14 lb)
CBS350-48T-4X 3.95 kg (8.71 lb)
CBS350-48P-4X 5.43 kg (11.97 lb)
CBS350-48FP-4X 5.82 kg (12.83 lb)
CBS350-8MGP-2X 2.5 kg (5.51 lb)
CBS350-8MP-2X 2.74 kg (6.04 lb)
CBS350-24MGP-4X 3.99 kg (8.79 lb)
CBS350-12NP-4X 4.24 kg (9.35 lb)
CBS350-24NGP-4X 5.3 kg (11.68 lb)
CBS350-48NGP-4X 5.95 kg (13.12 lb)
CBS350-8XT 2.98 kg (6.57 lb)
CBS350-12XS 3.42 kg (7.54 lb)
CBS350-12XT 2.93 kg (6.46 lb)
CBS350-16XTS 3.79 kg (8.36lb)
CBS350-24XS 4.4 kg (9.7 lb)
CBS350-24XT 5.1 kg (11.2 lb)
CBS350-24XTS 4.84 kg (10.67 lb)
CBS350-48XT-4X 7.29 kg (16.1 lb)
Power 100-240V 50-60 Hz, internal, universal : CBS350-8P-2G, CBS350-8FP-2G, CBS350-16T-2G, CBS350-16P-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-24S-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G, CBS350-24T-4X, CBS350-24P-4X, CBS350-24FP-4X, CBS350-48T-4X, CBS350-48P-4X, CBS350-48FP-4X, CBS350-8MGP-2X, CBS350-8MP-2X, CBS350-24MGP-4X, CBS350-12NP-4X, CBS350-24NGP-4X, CBS350-48NGP-4X, CBS350-8XT, CBS350-12XS, CBS350-12XT, CBS350-16XTS, CBS350-24XS, CBS350-24XT, CBS350-24XTS, CBS350-48XT-4X

100-240V 50-60 Hz, external : CBS350-8T-E-2G, CBS350-8P-E-2G, CBS350-8FP-E-2G, CBS350-8S-E-2G, CBS350-16T-E-2G, CBS350-16P-E-2G

Certification UL (UL 62368), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A
Operating temperature 23° to 122°F (-5° to 50°C)

CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G, CBS350-16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G, CBS350-24T-4X, CBS350-24P-4X, CBS350-24FP-4X, CBS350-48T-4X, CBS350-48P-4X, CBS350-48FP-4X

32° to 122°F (0° to 50°C)

CBS350-8S-E-2G, CBS350-24S-4G, CBS350-24MGP-4X, CBS350-12NP-4X, CBS350-24NGP-4X, CBS350-48NGP-4X, CBS350-8XT, CBS350-12XS, CBS350-12XT, CBS350-16XTS, CBS350-24XS, CBS350-24XT, CBS350-24XTS, CBS350-48XT-4X

32° to 113°F (0° to 45°C)

CBS350-8MGP-2X, CBS350-8MP-2X

Storage temperature -13° to 158°F (-25° to 70°C)
Operating humidity 10% to 90%, relative, non-condensing
Storage humidity 10% to 90%, relative, non-condensing
Acoustic noise and Mean Time Between Failure (MTBF) Model Name FAN (Number) Acoustic Noise MTBF at 25°C (hours)
CBS350-8T-E-2G Fanless N/A 2,171,669
CBS350-8P-2G Fanless N/A 1,786,412
CBS350-8P-E-2G Fanless N/A 1,706,649
CBS350-8FP-2G Fanless N/A 1,786,412
CBS350-8FP-E-2G Fanless N/A 1,706,649
CBS350-8S-E-2G Fanless N/A 2,242,229
CBS350-16T-2G Fanless N/A 2,165,105
CBS350-16T-E-2G Fanless N/A 2,165,105
CBS350-16P-2G Fanless N/A 706,983
CBS350-16P-E-2G Fanless N/A 706,983
CBS350-16FP-2G Fanless N/A 706,983
CBS350-24T-4G Fanless N/A 2,026,793
CBS350-24P-4G Fanless N/A 698,220
CBS350-24FP-4G 1 25°C : 34.8 dBA 698,220
CBS350-24S-4G Fanless N/A 258,544
CBS350-48T-4G 1 25°C : 29.7 dBA 1,452,667
CBS350-48P-4G 1 25°C : 37.3 dBA 856,329
CBS350-48FP-4G 1 25°C :48.7 dBA 856,301
CBS350-24T-4X Fanless N/A 2,026,793
CBS350-24P-4X Fanless N/A 698,220
CBS350-24FP-4X 1 25°C : 34.8 dBA 698,220
CBS350-48T-4X 1 25°C : 29.7 dBA 1,452,667
CBS350-48P-4X 1 25°C :37.3 dBA 856,329
CBS350-48FP-4X 1 25°C :48.7 dBA 856,301
CBS350-8MGP-2X Fanless N/A 1,524,625
CBS350-8MP-2X 1 25°C : 41.3 dB 1,237,940
CBS350-24MGP-4X 3 25°C : 40.5 dB 1,033,942
CBS350-12NP-4X 3 25°C : 39.4 dB 553,218
CBS350-24NGP-4X 3 25°C : 40.4 dB 562,415
CBS350-48NGP-4X 4 25°C : 39.6 dB 316,088
CBS350-8XT 2 25°C : 40.8 dB 1,418,411
CBS350-12XS 4 25°C : 45.8dB 1,385,554
CBS350-12XT 2 25°C : 40.5 dB 633,324
CBS350-16XTS 3 25°C : 39.1dB 798,504
CBS350-24XS 4 25°C : 43.0 dB 1,356,179
CBS350-24XT 4 25°C : 41.2 dB 556,642
CBS350-24XTS 3 25°C : 43.3dB 1,372,246
CBS350-48XT-4X 5 25°C : 47.9 dB 287,135